Chapter 2 Fault Management System 89
Business Communications Manager - Management User Guide
Alarm Analysis and Clearing Procedures
Use the information in this section to identify, analyze and clear alarm events. This section
describes alarm messages and appropriate, associated maintenance activities (see the “Alarm
clearing flow chart” on page 89). Use the information in this section as a reference to interpret and
act upon event notifications from your alarm interface.
Use the Unified Manager interface to detect events that affect
system performance or function
• The alarm banner and alarm browser (primary Unified Manager interface for alarm detection).
• The phone alarm (if configured) provides both a visual and audible indication of an MSC
alarm event.
• The event logs displayed through the SNMP trap watcher application provide supporting
information or as an alternative event reporting tool.
• The system test log provides supporting alarm information (for MSC events only).
Figure 28 Alarm clearing flow chart
Routine monitoring process
Alternative monitoring process
Examine Alarm
Banner
Alarm event
Examine Alarm
Browser
Examine Alarm
Phone - MSC
Event
Examine
SNMP trap
Examine
System test
logs (MSC
events only)
Follow recommended action indicated in alarm description
No
Yes Other alarm?
End
Analysis & Resolution process
Locate alarm event in Component ID (alarm)/eventSource (trap) summary on page 92