Avaya BCM Management Guia do Utilizador Página 241

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 488
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 240
Chapter 2 Fault Management System 237
Business Communications Manager - Management User Guide
VoiceWatchdog
VoiceWatchdog Return to table: Component ID (alarm)/eventSource (trap) summary
Return to table: Component ID alarms/eventSource (Trap) by event ID
Service: Voice watchdog
Event ID: 1000 Message: KSU Down.
User action: Telephony services will be stopped temporarily. The alarm KSU_UP
will be received when the telephony services are being restarted.
Alarm severity: Warning
Trap-type: Information
Logs: None
Comments: Voice Watchdog received the KSU Down from the VoiceMSCService.
All services depending on VoiceMSCService will stopped
Event ID: 1001 Message: KSU Reset.
User action: Telephony services being restarted and will be up within 10~15
minutes.
Alarm severity: Warning
Trap-type: Information
Logs: None
Comments: Voice Watchdog received the KSU UP from the VoiceMSCService.
VoiceMSCDriver and all its dependencies will be stopped/Restarted.
Wait for 15 minutes to get telephone sets back.
Event ID: 1002 Message: KSU UP.
User action: Telephony services being restarted and will be up within 10~15
minutes.
Alarm severity: Warning
Trap-type: Information
Logs: None
Comments: Voice Watchdog received the KSU UP from the VoiceMSCService,
VoiceMSCDriver and all its dependencies will be Restarted. Wait for
15 minutes to get telephone sets back.
Event ID: 1003 Message: %Date/Time% Received KSU DN Length change notice.
User action: No action required. Voice Watchdog received the KSU DN Length
change from the VoiceMSCService, VoiceMSCDriver and all its
dependencies will be stopped/Restart. Wait for 15 minutes to get
telephone sets back.
Alarm severity: Warning
Trap-type: Information
Logs: None
Event ID: 1004 Message: Restarting All Monitored Services.
User action: No action required. Voice Watchdog restarting the root service and all
it's dependencies.
Alarm severity: Warning
Trap-type: Information
Logs: None
Vista de página 240