182 Chapter 2 Fault Management System
P0609330 2.0
User action: 1. Check the Power Supply (Module1, Module2 on redundant System)
2.Check Power Supply Fan1 3.Check Power Supply Fan2
Alarm severity: Critical
Trap-type: Error
Logs: None
Comments: 1. SSM detects there is a failure in one of the power supply modules.
2. SSM detects there is a failure in power supply Fan1 3. SSM detects
there is a failure in power supply Fan2
Event ID: 3013 Message: 1. CPU Fan Stopped. 2. %Fan1 Value% Below Tolerance %#% 3.
%Fan2 Value% Below Tolerance %#%
User action: 1. Check CPU Fan 2. Check Fan 1 3. Check Fan 2
Alarm severity: Critical
Trap-type: Error
Logs: None
Comments: 1. CPU Fan stopped or failed. 2. Fan 1 speed below tolerance level
%#% 3. Fan 2 speed below tolerance level %#%
Event ID: 3014 Message: 1. DupliDisk Mirroring Kit not found. 2. DupliDisk Mirroring failed.
3. Mirror Software shut down. 4. Mirror Master HDD failed reading/
Writing
5. Primary Master HDD Failed. Reading/Writing. 6. Replacement HDD
Smaller than Active Drive. 7. Mirror HDD Smaller than Active Drive. 8.
Check Mirror Master HDD. 9. Check Primary Master HDD.
User action: 1. Check DupliDisk Mirroring KIT. 2. Check DupliDisk Mirroring KIT. 3.
Check SSM status. 4. Check Mirror Master HDD power/Data cable. 5.
Check Mirror Master HDD power/Data cable. 6, 7. Replacement HDD
size should be equal or Larger that the Active HDD. 8. Check Mirror
Master HDD. 9. Check Primary Master HDD.
Alarm severity: Critical
Trap-type: Error
Logs: None
Comments: 1. SSM failed to detect the RAID CARD (Disk Mirroring). 2. SSM
detects there is a failure in Disk Mirroring HW or DLL. 3. SSM Detects
the Mirror software shuts it self down. 4. SSM detects there is a failure
in Primary Master HDD 5. SSM detects there is a failure in Mirror
Master HDD. 6, 7. Replacement HDD size should be equal or Larger
that the Active HDD. 8. Mirror Master HDD not working properly. 9.
Primary Master HDD not working properly.
Event ID: 3015 Message: CPU Temperature Above Tolerance 100 °C for more than two
Minutes, SSM shutting down the power supply
User action: BCM 1000 will reboot automatically, BCM200/400 need restart.
Alarm severity: Critical
Trap-type: Error
Logs: None
Comments: CPU Temperature Above Tolerance 100 °C for more than two
Minutes, SSM shutting down the power supply
Event ID: 3016 Message: Non-paged memory on its capacity, SSM rebooting the BCM
User action: BCM 1000 will reboot automatically, BCM200/400 need restart.
System Status
Monitor
Return to table: Component ID (alarm)/eventSource (trap) summary