Chapter 10 Testing, Troubleshooting, and Diagnostics 459
Business Communications Manager - Management User Guide
3 To set the parameters for the System Status Sanity check, click the LED Settings tab.
The LED Settings record appears (see Figure 62).
Figure 62 System Status Monitor LED (SSM) Settings record screen
Table 35 lists the values shown on the LED Settings record screen.
Temperature The LED is green when the temperature in your system is within the accepted limits. If this
changes, the LED turns red.
Fan The LED is green when the fan, or fans, in your system are operating correctly. If one or
more fans fail, or malfunction, the LED turns red.
Table 35 LED Display screen settings
Attribute Values Description
F/W Version Read only. The current version of the LED monitoring application.
Sanity Reset Enable
Disable
Determine whether the system resets if communication between
the System Status Monitor and the System Status Monitor
Service is lost.
Sanity Interval 60-255
Default: 240
The time in seconds between sanity checks, before a timeout
occurs.
Sanity Timeout 0-254
Default: 10
The number of timeouts before the system status monitor sends
a reset signal to the computing platform.
SSM status Read only This field indicates the current status of the System Services
Monitor itself. This field must be set to Up to show the current
status of the equipment.
Table 34 System Status Monitor LED descriptions
LED Description