154 Chapter 2 Fault Management System
P0609330 2.0
Perfctrs
Perfctrs provides the performance counters component on the BCM.
Perflib
Perflib provides a performance counters library on the BCM.
Perfctrs Return to table: Component ID (alarm)/eventSource (trap) summary
Return to table: Component ID alarms/eventSource (Trap) by event ID
Service: None
Event ID: 3101 Message: Unable to read IO control information from NBT device.
User action: In most cases, no action is required. However, please check if the
network connections of the BCM are working.
Alarm severity: Critical
Trap-type: Error
Logs: None
Comments: Refer to Microsoft Article Q275586. NBT=NetBIOS over TCP/IP. THis
can happen when trying to monitor statistics from and inactive network
adapter. It can generally be ignored.
Perflib Return to table: Component ID (alarm)/eventSource (trap) summary
Return to table: Component ID alarms/eventSource (Trap) by event ID
Service: None
Event ID: 1008 Message: The Open Procedure for service "RasRad" in DLL "rasrad.dll" failed.
Performance data for this service will not be available. Status code
returned is DWORD 0.
User action: This event should not be seen in BCM 3.0. In case of its occurrence in
a BCM 3.0 machine, please contact Nortel Networks support team.
Alarm severity: Critical
Trap-type: Error
Logs: None
Event ID: 2002 Message: The open procedure for service (service name) in DLL (DLL name)
has taken longer than the established wait time to complete. The wait
time in milliseconds is shown in the date.
User action: No action required. However, please report the message indicating the
service name and the DLL name to support.
Alarm severity: Minor
Trap-type: Warning
Logs: None