70 Chapter 2 Fault Management System
P0609330 2.0
Figure 20 Alarm manager database fields
2 Use the information from the following table to configure the Alarm Database:
Table 3 Alarm Database settings
Attribute Description
Maximum Number
Record
Allows you to set the maximum number of records that the alarm database stores. The default is
0 (no limit).
The range is from 0 to 5000 records. If you enter 0, there is no limit to the number of records.
When the number of records reaches the maximum, the earliest record is removed to make
room for the new alarm record.
Kept Timer (days) Allows you to set the number of days that the records remain in the database before the records
are archived.
Resync Timer
(seconds)
Allows you to set, in seconds, the interval at which the alarm service initiates a synchronization
operation with the Business Communications Manager's internal event logs. This
synchronization is in addition to the normal synchronization operations triggered by the arrivals
of new events.