Chapter 2 Fault Management System 227
Business Communications Manager - Management User Guide
Trap-type: Warning
Logs: MSC event 617, Sev=P4, Cat=A
Event ID: 639 Message: A bad message has been received by a CAP while getting key
information. Contact the installer to get the event traceback data.
User action: Contact the installer to get the event traceback data.
Alarm severity: Minor
Trap-type: Warning
Logs: MSC event 639, Sev=P4, Cat=A
Event ID: 799 Message: A call processing error has occurred on an ISDN line. No action
required.
User action: No action required
Alarm severity: Minor
Trap-type: Warning
Logs: MSC event 799, Sev=P7, Cat=B
Event ID: 894 Message: An attempt was made to enqueue a message into the DASS2/DPNSS
layer 3 flow control queue, but the queue was full. The message has
been dropped, and will not be sent out to the network. This can arise if
the link has gone down but the Digital Trunk Interface module has
failed to report it. Port = %1. Customer should report the problem.
Installer should verify that the link is operational and the module is still
functioning.
User action: Customer should report the problem. Installer should verify that the
link is operational and the module is still functioning.
Alarm severity: Minor
Trap-type: Warning
Logs: MSC event 894, Sev=P4, Cat=C
Event ID: 901 Message: Part or all of the telephony system memory has been corrupted. A
coldstart of the telephony subsystem will occur. This problem should
be reported. All telephony data will need to be reprogrammed.
User action: Report the problem. All telephony data will need to be reprogrammed.
Alarm severity: Critical
Trap-type: Error
Logs: MSC event 901, Sev=P8, Cat=F
Event ID: 949 Message: A bad protocol call control has been received from the Basic Rate
Interface module. Determine reason for event and resolve.
User action: Determine reason for event and resolve.
Alarm severity: Minor
Trap-type: Warning
Logs: MSC event 949, Sev=P6, Cat=B
Event ID: 998 Message: Telephony time has been synchronized with the System time.
User action: No action required.
Alarm severity: Critical
Trap-type: Error
Logs: MSC event 998, Sev=P4, Cat=B
Voice software Return to table: Component ID (alarm)/eventSource (trap) summary