Chapter 2 Fault Management System 103
Business Communications Manager - Management User Guide
Event ID: 258 Message: Shutdown complete.
User action: No action required.
Alarm severity: Warning
Trap-type: Information
Logs: None
Event ID: 772 Message: IP Music Error: Integrated MOH player - unable to initialize network
connection. Service shutting down.
User action: Disable the BcmAmp player by configuring your IP Music source as
either: Audio Jack or Network Audio. Contact Customer Support for
further assistance.
Alarm severity: Critical
Trap-type: Error
Logs: None
Event ID: 773 Message: IP Music Error: Integrated MOH player - initialization error. Unable to
proceed. Service shutting down.
User action: If stopping and starting the IP Music service via the Unified Manager
fails to rectify the problem, disable the IP Music service and contact
Customer Support for further assistance.
Alarm severity: Critical
Trap-type: Error
Logs: None
Event ID: 774 Message: IP Music Error: Integrated MOH player - initialization failure. Service
shutting down.
User action: If stopping and starting the IP Music service via the Unified Manager
fails to rectify the problem, please disable the IP Music service and
contact Customer Support for further assistance.
Alarm severity: Critical
Trap-type: Error
Logs: None
Event ID: 775 Message: IP Music Error: Integrated MOH player - unable to allocate resources.
Service shutting down.
User action: If stopping and starting the IP Music service via the Unified Manager
fails to rectify the problem, please disable the IP Music service and
contact Customer Support for further assistance.
Alarm severity: Critical
Trap-type: Error
Logs: None
BcmAmp Return to table: Component ID (alarm)/eventSource (trap) summary
Comentários a estes Manuais