Chapter 2 Fault Management System 215
Business Communications Manager - Management User Guide
Alarm severity: Critical
Trap-type: Error
Logs: MSC event 322, Sev=P8, Cat=F
Event ID: 50 Message: A Digital Station Computer Module on bus %1 has been disconnected
or powered down.
User action: Power down the system and check all connections to the module. If
the problem persists, replace the module.
Alarm severity: Critical
Trap-type: Error
Logs: MSC event 250, Sev=P9, Cat=C
Comments: MSCid=250, Sev=P9, Cat=C. On system boot-up the BCM waits 3
minutes before reporting alarm 50/51 to give the modules time to boot
up. On a running system the BCM requires a module to be lost for at
least 2 minutes before reporting alarm 50/51.
Event ID: 51 Message: A Digital Trunk Computer Module or Called ID Computer Module on
bus %1 has been disconnected or powered down.
User action: Power down the system and check all connections to the module. If
the problem persists, replace the module.
Alarm severity: Critical
Trap-type: Error
Logs: MSC event 251, Sev=P9, Cat=C
Comments: MSCid=251, Sev=P9, Cat=C. On system boot-up the BCM waits 3
minutes before reporting alarm 50/51 to give the modules time to boot
up. On a running system the BCM requires a module to be lost for at
least 2 minutes before reporting alarm 50/51.
Event ID: 52 Message: A Trunk Computer Module has been disconnected. Event parameters:
%1 (Module - Card).
User action: Power down the system and check all connections to the module.
Check that the module is properly seated. If the problem persists,
replace the module.
Alarm severity: Critical
Trap-type: Error
Logs: MSC event 252, Sev=P9, Cat=C
This only applies to trunk MBMs that share a DS30 bus. So CTM and
BRI MBMs can generate this. To reproduce this bring 2 CTMs or BRI
MBMs on a single DS30 and disconnect 1 of the MBMs. ON a running
system the BCM requires a module to be lost for at least 2 minutes
before reporting alarm 50/51/52.
Event ID: 53 Message: Radio %1 has been removed from service due to an error. An
accompanying Event message will indicate an explicit reason for the
radio failure.
User action: Perform diagnostics on the basestation.
Alarm severity: Critical
Trap-type: Error
Logs: MSC event 300, Sev=P6, Cat=C
Voice software Return to table: Component ID (alarm)/eventSource (trap) summary