Chapter 2 Fault Management System 211
Business Communications Manager - Management User Guide
Voice software
Voice software Return to table: Component ID (alarm)/eventSource (trap) summary
Return to table: Component ID alarms/eventSource (Trap) by event ID
Service: Voice software alarm monitor
Event ID: 11 Message: All lines were disconnected. Power down the system and check all line
connections on the system.
User action: Power down the system and check all telephone connections on the
system.
Alarm severity: Critical
Trap-type: Error
Logs: MSC event 254, Sev=P9, Cat=C
Event ID: 18 Message: DSP message queue (messages to be sent to DSP firmware) is full.
Message not sent may cause application to timeout waiting for
resource. Users may experience call failures.
User action: Customer should report event to installer to get tracebacks.
Alarm severity: Minor
Trap-type: Warning
Logs: MSC event 254, , Sev=P9, Cat=C
Event ID: 20 Message: Wireless re-evaluation required. Initiate data re-evaluation.
User action: Re-Evaluation should be initiated by the system administrator.
Alarm severity: Critical
Trap-type: Error
Logs: MSC event 665, Sev=P8, Cat=F
Event ID: 21 Message: Wireless re-evaluation in progress.
User action: No action required. This ALARM only alerts the system administrator/
installer that mobility data re-evaluation has started.
Alarm severity: Warning
Trap-type: Information
Logs: MSC event 878, Sev=?, Cat=E
Event ID: 22 Message: Wireless re-evaluation completed.
User action: No action required. This aALARM only alerts the system administrator/
installer that mobility data re-evaluation has finished.
Alarm severity: Warning
Trap-type: Information
Logs: MSC event 879, Sev=?, Cat=E
Event ID: 23 Message: Configured cell %1 (cell number) failed to come on-line.
User action: Determine which basestations belong to the failed cell. Replace the
basestations and invoke a data re-evaluation, or warm start the
system.
Alarm severity: Critical
Trap-type: Error
Logs: MSC event 881, Sev=?, Cat=F
Event ID: 24 Message: Etiquette: There is insufficient data to capture an RSSI signature.
Vista de página 214