214 Chapter 2 Fault Management System
P0609330 2.0
User action: Check the logs and look for Events ranging from 315-336. If this alarm
occurs more than once over a two-week period, contact your local
support group.
Alarm severity: Critical
Trap-type: Error
Logs: MSC event 318
Event ID: 44 Message: The long term alarm threshold has been surpassed in DTCM %1 for
the detection of Remote Alarm Indication. The most likely cause is an
irregularity with the PSTN connections. The cable connecting the
DTCM to the network termination point or external CSU has been
disconnected, or there is a problem with the signal from the network.
User action: Check the logs and look for Events ranging from 315-336. If this alarm
occurs more than once over a two-week period, contact your local
support group.
Alarm severity: Critical
Trap-type: Error
Logs: MSC event 319, Sev=P8, Cat=F
Event ID: 45 Message: The long term alarm threshold has been surpassed in DTCM %1 for
the detection of Loss of Signal on time-slot 16. The most likely cause
is an irregularity with the PSTN connections. The cable connecting the
DTCM to the network termination point or external CSU has been
disconnected, or there is a problem with the signal from the network.
User action: Check the logs and look for Events ranging from 315-336. If this alarm
occurs more than once over a two-week period, contact your local
support group.
Alarm severity: Critical
Trap-type: Error
Logs: MSC event 320, Sev=P8, Cat=F
Event ID: 46 Message: The long term alarm threshold has been surpassed in DTCM %1 for
the detection of Alarm Indication Signal on time-slot 16. The most
likely cause is an irregularity with the PSTN connections. The cable
connecting the DTCM to the network termination point or external CSU
has been disconnected, or there is a problem with the signal from the
network.
User action: Check the logs and look for Events ranging from 315-336. If this alarm
occurs more than once over a two-week period, contact your local
support group.
Alarm severity: Critical
Trap-type: Error
Logs: MSC event 321, Sev=P8, Cat=F
Event ID: 47 Message: The long term alarm threshold has been surpassed in DTCM %1 for
the detection of Remote Alarm Indication on time-slot 16. The most
likely cause is an irregularity with the PSTN connections. The cable
connecting the DTCM to the network termination point or external CSU
has been disconnected, or there is a problem with the signal from the
network.
User action: Check the logs and look for Events ranging from 315-336. If this alarm
occurs more than once over a two-week period, contact your local
support group.
Voice software Return to table: Component ID (alarm)/eventSource (trap) summary
Comentários a estes Manuais