Configuring WAN Line Services
2-6
308648-14.00 Rev 00
Setting the BofL Timeout
The BofL Timeout parameter specifies the time between transmissions of BofL
messages from this synchronous interface. This parameter is valid only when
BofL is enabled.
By default, the BofL timeout period is 5 seconds. Timeout occurs when five
periods elapse without both a successful frame transmission and a successful
reception. When timeout occurs, the router disables and reenables the
synchronous line. For example, with this parameter set to 5 seconds, the interface
must successfully transmit and receive a frame within 25 seconds. Timeout occurs
in 25 seconds.
Set the BofL timeout to a value from 1 to 60 seconds on the interface.
Using the BCC
To set BofL timeout, navigate to the serial prompt (for example,
box
;
serial/2/1
)
and type:
bofl-timeout
integer
For example:
serial/2/1#
bofl-timeout 20
Using Site Manager
See the BofL Timeout parameter on page A-70 for information.
Setting the MTU
The maximum transmission unit (MTU) is the largest frame that the router can
transmit on this line.
For X.25, specify a value of at least 5 bytes more than the maximum packet size
for the packet level.
The MTU is 1600 bytes by default. Set the MTU from 3 to 4608 bytes on the
interface.