Site Manager Parameters
308648-14.00 Rev 00
A-33
Parameter: Accept Loopback Request
Path: MCT1 Connector > Edit Logical Lines > Port Details > MCT1 Port Parameters
Default: Enable
Options: Enable
|
Disable
Function: Enables or disables loop-up and loop-down code detection. When this
parameter is enabled, this port accepts and complies with requests to go into
loopback mode from a remote device.
Instructions: Enable or disable local loopback.
MIB Object ID: 1.3.6.1.4.1.18.3.4.9.3.1.10
Parameter: Loopback Configuration
Path: MCT1 Connector > Edit Logical Lines > Port Details > MCT1 Port Parameters
Default: No Loopback
Options: No Loopback
|
Payload Loopback
|
Line Loopback
Function: Forces the DS1 interface to go into loopback. The remote or intermediate
equipment then performs diagnostics on the network between that equipment
and the DS1 interface:
• No Loopback -- This option deactivates any loopback.
• Payload Loopback -- The received signal on this interface is looped through the
device. Typically, the received signal is looped back for retransmission after it has
passed through the framing device.
• Line Loopback -- The received signal does not go through the framing device
(minimum penetration) but is looped back out.
Instructions: Select the loopback configuration option for testing. After testing, set this
parameter to No Loopback to return the interface to normal operation.
MIB Object ID: 1.3.6.1.4.1.18.3.4.9.4.1.10