Configuring BayStack DSU/CSU Services
308648-14.00 Rev 00
4-9
Using the BCC
To change the loopback test state, navigate to the dsucsu prompt (for example,
box; dsucsu/1/1) and type:
loopback-mode
variable
For example:
dsucsu/1/1# loopback-mode local-analog-loopback
Using Site Manager
To configure DSU/CSU loopback testing, complete the following tasks.
Selecting a loopback test state disrupts user data transmission through the
DSU/CSU for a period specified by the V.54 Timer parameter.
Configuring the V.54 Loopback Timer
You must set the duration, in seconds, for the loopback testing specified in the
V.54 Loopback parameter. The default value, zero (0), indicates that loopback
testing runs indefinitely.
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
click on the COM connector for the DSU/
CSU circuit.
The Edit Connector window opens.
2. Click on
Edit DSU/CSU
. The Edit Adapter Module DSU CSU
Parameters window opens.
3. Edit the
V.54 Loopback
and
V.54 Timer
parameters.
Click on
Help
or see the parameter
descriptions beginning on page A-9.
4. Click on
OK
.
Caution:
If the only connection with the remote router is through the
DSU/CSU, be sure to specify a nonzero value, since loopback testing prevents
the local router from communicating with the remote DSU/CSU.