Configuring BayStack DSU/CSU Services
308648-14.00 Rev 00
4-7
For example:
dsucsu/1/1# line-availability-time 10
Setting the Poll Rate
In the BCC, the Poll Rate parameter indicates the number of seconds between
polls for DSU/CSU line status. A value of 1, which is the default, forces polling of
the DSU/CSU interface every second. Specify a value from 1 to 60 seconds.
Using the BCC
To change the poll rate, navigate to the dsucsu prompt (for example,
box; dsucsu/1/1) and type:
poll-rate
integer
For example:
dsucsu/1/1# poll-rate 60
Resetting the CQMS Counters
In the BCC, the CQMS Reset parameter resets the CQMS counters to their default
values. By default, the CQMS Reset parameter is disabled (cleared).
Using the BCC
To reset the CQMS counters, navigate to the dsucsu prompt (for example,
box; dsucsu/1/1) and type:
cqms-reset
variable
For example:
dsucsu/1/1# cqms-reset reset