Configuring WAN Line Services
7-58
308648-14.00 Rev 00
To set the port test parameters, complete the following tasks.
Enabling or Disabling BERT Mode
Enable BERT mode for BERT testing using Site Manager.
By setting this parameter, you enable or disable BERT mode on all logical lines
except QMCT1 and DMCT1 net module interfaces. On these interfaces, you can
enable or disable BERT mode on individual logical lines.
See the BERT Mode parameter on page A-41 for information.
Setting the BERT Alarm Type
Using Site Manager, you can specify the type of alarm signal to be generated
while in BERT mode, or disable the generation of alarm signals altogether.
See the BERT Alarm Type parameter on page A-41 for information.
Site Manager Procedure
You do this System responds
1. In dynamic mode, click on a configured
MCT1 or MCE1 connector in the
Configuration Manager window.
The Logical Lines window opens.
2. Click on
Port Details.
The Port Parameters window opens.
3. Click on
Line Tests.
Note that the Line
Tests option appears only in dynamic
mode
.
The Port Actions window opens.
4. Edit the port action parameters, located in
the upper portion of the window.
5. After setting a parameter, click on
Apply
.
6. Click on
Done
when you are finished
setting port action parameters.
Note:
All changes you apply to the port in the Port Actions window are in
effect only while the window is active. When you exit the Port Actions
window, all port settings revert to the original settings.