Configuring FT1 Services
308648-14.00 Rev 00
8-19
Setting the External Clock State
In the BCC, the External Clock State parameter indicates whether the external
clock is operational. You can set this parameter to present (up), which is the
default, or absent (down).
Using the BCC
To set the external clock state, navigate to the ft1 prompt (for example,
box
;
ft1/1/1
) and type:
external-clock-state
variable
For example:
mce1/1/2/1#
external-clock-state absent
Setting the Loop Clock
In the BCC, the Loop Clock State parameter specifies this port’s loop clock status.
You can set this parameter to present (up), which is the default, or absent (down).
Using the BCC
To set the loop clock state, navigate to the ft1 prompt (for example,
box
;
ft1/1/1
)
and type:
loop-clock-state
variable
For example:
ft1/1/1#
loop-clock-state absent