Configuring WAN Line Services
A-34
308648-14.00 Rev 00
QMCT1 and DMCT1 Port Parameters
In addition to the parameters described in the previous section, the Port
Parameters window for the QMCT1 and QMCT1 w/ DS0A link modules and the
DMCT1 net module includes four configurable parameters.
Parameter: Send Performance Measurement CR Addr
Path: QMCT1 Connector > Edit Logical Lines > Port Details > MCT1 Port
Parameters
Default: Customer Inst
Options: Customer Inst
|
Carrier
Function: Specifies the source of performance messages. Customer Inst indicates that the
customer installation supplies the messages; Carrier indicates that the carrier
supplies the messages.
You configure this parameter for QMCT1 link modules only.
Instructions: Select the source for outgoing performance messages.
MIB Object ID: 1.3.6.1.4.1.18.3.4.9.3.1.18
Parameter: Accept Perf Measurement CR Addr
Path: QMCT1 Connector > Edit Logical Lines > Port Details > MCT1 Port
Parameters
Default: Customer Inst
Options: Customer Inst
|
Carrier
Function: Specifies the source from which the router accepts performance messages.
Customer Inst indicates that the router accepts messages only from the customer
installation; Carrier indicates that the router accepts messages only from the
carrier.
You configure this parameter for QMCT1 link modules only.
Instructions: Select the source for inbound performance messages.
MIB Object ID: 1.3.6.1.4.1.18.3.4.9.3.1.19