Configuring WAN Line Services
9-6
308648-14.00 Rev 00
Using the BCC
To enable or disable the FE1 port, navigate to the fe1 prompt (for example,
box
;
fe1/1/1
) and type:
state
variable
For example:
fe1/1/1#
state disabled
Using Site Manager
See the Enable/Disable parameter on page A-58 for information.
Setting the FE1 Line Type
Select one of the following line types (frame formats) for your E1 equipment:
Using the BCC
To set the line type, navigate to the fe1 prompt (for example,
box
;
fe1/1/1
) and
type:
framing
variable
For example:
fe1/1/1#
framing e1
Using Site Manager
See the Line Type parameter on page A-58 for information.
Table 9-3. FE1 Line Type Options
BCC Option Site Manager Option
e1 E1
e1-crc E1 CRC
e1-mf E1 MF
e1-crcmf E1 CRC MF
unframed-e1 Unframed E1