Configuring MCE1 and MCT1 Services
308648-14.00 Rev 00
7-27
Using Site Manager
See the Accept Perf Measurement CR Addr parameter on page A-34 for
information.
Setting the Primary Clock Source
Timing is independent for the two ports on a DMCT1 net module, and for the four
ports on a QMCT1 or QMCT1 w/ DS0A link module. For these modules, you
select the timing source for each port.
Table 7-11
shows the primary source options for timing signals:
Note:
DMCE1 and DMCT1 link modules contain a single clock chip that
provides the timing signals for both ports. Therefore, clock parameters that
you set for the first port apply to the second port on the module.
Table 7-11. Primary Clock Source Options
BCC Options Site Manager Options Description
internal Internal Uses the clock chip on the MCT1 module
loop1 Port 1 Ext Loop The default; uses the signal coming in from
port 1
loop2 Port 2 Ext Loop Uses the signal coming in from port 2
loop3 Port 3 Ext Loop Uses the signal coming in from port 3 on a
QMCT1
loop4 Port 4 Ext Loop Uses the signal coming in from port 4 on a
QMCT1
external Auxiliary Ext Uses an external source via port 1 on a
QMCT1
Note:
External clocking via port 1 requires a special Y-cable, Nortel Networks
Order No. AA0018006.