Configuring MCE1 and MCT1 Services
308648-14.00 Rev 00
7-29
Using Site Manager
See the Secondary Clock parameter on page A-35 for information.
Setting the Loop Clock
In the BCC, the Loop Clock State parameter specifies the MCE1 port’s loop clock
status. You can set this parameter to present (up), which is the default, or
absent (down).
Using the BCC
To set the loop clock state, navigate to the mce1 prompt (for example,
stack
;
mce1/1/2/1
) and type:
loop-clock-state
variable
For example:
mce1/1/2/1#
loop-clock-state absent
Setting the External Clock
In the BCC, the External Clock State parameter indicates whether the external
clock is operational. You can set this parameter to present (up), which is the
default, or absent (down).
Using the BCC
To set the external clock state, navigate to the mce1 prompt (for example,
stack
;
mce1/1/2/1
) and type:
external-clock-state
variable
For example:
mce1/1/2/1#
external-clock-state absent
Setting Buffer Credits for MCT1
See “Setting Buffer Credits for MCE1” on page 7-14 for details about how to set
the Transmit Buffer Use Credits and Receive Buffer Use Credits parameters using
the BCC.