Configuring WAN Line Services
8-26
308648-14.00 Rev 00
Setting the BofL Timeout
The time period between transmissions of BofL packets is 5 seconds by default.
You can change the BofL timeout value on the logical line to any value from 1 to
60 seconds.
Using the BCC
To change the BofL timeout value, navigate to the logical-line prompt (for
example,
box
;
ft1/1/1
;
logical-line/1/1
) and type:
bofl-timeout
integer
For example:
logical-line/1/1#
bofl-timeout 10
Using Site Manager
See the BofL Timeout parameter on page A-51 for information.
Enabling or Disabling Logical Line Loopback
In logical line (channelized) loopback mode, the router retransmits received data
for specified timeslots only. This proprietary, SNMP-based form of loopback
passes data through the HDLC controller, and therefore only supports HDLC data.
Logical line loopback mode is disabled by default.
You can specify whether or not to initiate logical line loopback mode on the
logical line using Site Manager.
Using Site Manager
See the Fractional Loopback parameter on page A-51 for information.