Configuring FT1 Services
308648-14.00 Rev 00
8-21
Specifying a Circuit Name
You can use the current circuit name or specify a new name. The current circuit
name identifies the following:
• Circuit type
• Physical connector (slot and port number)
• Number of the logical line on the FT1 port
To specify a new circuit name, navigate to the logical-line prompt (for example,
box
;
ft1/1/1
;
logical-line/1/1
) and type:
circuit-name
string
For example:
logical-line/1/1#
circuit-name ft1-newyork
Selecting a WAN Protocol
To configure a WAN protocol over this logical line, navigate to the logical-line
prompt (for example,
box
;
ft1/1/1
;
logical-line/1/1
) and type:
wan-protocol
variable
For example:
logical-line/1/1#
wan-protocol ppp
Setting the WAN Interface Type
The interface is set for synchronous operation by default. Set this parameter to
asynchronous to select asynchronous communication, or to pasynchronous for
polled asynchronous communication.
To set the WAN interface type, navigate to the logical-line prompt (for example,
box
;
ft1/1/1
;
logical-line/1/1
) and type:
wan-type
variable
For example:
logical-line/1/1#
wan-type asynchronous