Configuring MCE1 and MCT1 Services
308648-14.00 Rev 00
7-37
You can use the default name that appears in the Add Circuit window or
change the name by clicking on the Circuit Name box and typing a new name.
Figures 7-2
and 7-3 illustrate how Site Manager generates the default logical
line name. The default name identifies the following:
• Circuit type (MCE1 or MCT1)
• Physical connector (slot and port number)
• Number of the logical line on the MCE1 or MCT1 port
• Module number (ASN net modules only)
Figure 7-2. Default Circuit Name for Link Modules
Figure 7-3. Default Circuit Name for ASN Net Modules
6. Select the protocols to run on this logical
line. See the appropriate protocol
configuration guide for instructions.
The Logical Lines window opens,
showing the first MCE1 or MCT1 circuit.
7. Repeat steps 2 to 6 for each logical line
that you want to create.
Site Manager Procedure
(continued)
You do this System responds
Circuit name: MCE1_31_1
Type of circuit
Slot where connector
resides (Slot 3)
Connector position on
Link module (Port 1)
Logical line
LS0018A
Circuit name: MCE1_231_1
Type of circuit
Slot where connector
resides (Slot 2)
Connector position on
net module (Port 1)
Logical line
Module where connector
resides (Module 3)
LS0019A