Avaya Configuring WAN Lines Services Manual do Utilizador Página 147

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 462
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 146
Configuring MCE1 and MCT1 Services
308648-14.00 Rev 00
7-13
Setting the Line Impedance (MCE1 Net Modules Only)
The line impedance for the ASN MCE1 net module is 120 ohm by default. For the
ASN MCE1 net module only, you can change the line impedance to 75 ohm for
this MCE1 interface.
Using the BCC
To change line impedance, navigate to the mce1 prompt (for example,
stack
;
mce1/1/2/1
) and type:
line-impedance
variable
For example:
mce1/1/2/1#
line-impedance bnc-75-ohms
mce1/1/2/1#
line-impedance rj45-120-ohms
Using Site Manager
See the Line Impedance parameter on page A-27 for information.
Setting the FDL Loop Interframe Fill
In the BCC, the FDL Loop Interframe Fill parameter is set to mark by default.
This enables the detection of loop retention code when the remote end is in line or
payload loopback. When you set this parameter to loop-retention, the loop
retention interframe time fill for the facility data link (FDL) is enabled after
sending loop-up code.
Using the BCC
To set this parameter, navigate to the mce1 prompt (for example, |
stack
;
mce1/1/2/1
) and type:
fdl-loop-interframe-fill
variable
For example:
mce1/1/2/1#
fdl-loop-interframe-fill loop-retention
Vista de página 146
1 2 ... 142 143 144 145 146 147 148 149 150 151 152 ... 461 462

Comentários a estes Manuais

Sem comentários