Site Manager Parameters
308648-14.00 Rev 00
A-43
FT1 Port Application and Clock Parameters
Parameter: NRZI Type
Path: Configured QMCT1 Connector > MCT1 Logical Lines
Default: Mark
Options: Mark
|
Space
Function: The software uses this parameter only if you installed a QMCT1 DS0A link
module and you set the NRZI Enable parameter to Enable. This parameter
specifies the NRZI encoding type in the frame on the logical line. The Mark
format uses a 0-bit to indicate a state change and a 1-bit to indicate no state
change; the Space format uses the opposite.
Instructions: Ignore this parameter if you set NRZI Enable to Disable.
Otherwise, if you are configuring the router connection to
• The host side, determine which device on that side is using NRZI, and match this
parameter to the encoding type used by that device
• The remote access side, determine which device on that side is using NRZI, and
match this parameter to the encoding type used by that device
MIB Object ID: 1.3.6.1.4.1.18.3.4.9.6.1.67
Parameter: Port Application Mode
Path: Unconfigured FT1 Connector > Port Application
Default: NONPRI
Options: NONPRI
Function: Specifies the port application to use on the logical lines.
Instructions: Select NONPRI to indicate that all of the lines have a permanent circuit number
and are for leased lines, frame relay, or permanent connections to other
non-ISDN PRI applications.
MIB Object ID: 1.3.6.1.4.1.18.3.4.9.1.16
Comentários a estes Manuais