Configuring BayStack DSU/CSU Services
308648-14.00 Rev 00
4-5
For a Telco network, set both ends to slave. For a private-wire configuration, set
one end to Master and the other end to slave.
The Transmit Clock Source parameter is set to slave by default. Note that there
can be only one clock source on a DDS line.
Using the BCC
To change the clock source, navigate to the dsucsu prompt (for example,
box
;
dsucsu/1/1
) and type:
clock-master
variable
For example:
dsucsu/1/1#
clock-master master
Using Site Manager
See the Transmit Clock Source parameter on page A-8 for information.
Resetting the Router
In the BCC, the Unit Reset parameter enables you to reset the router remotely,
causing it to terminate all connections. The Unit Reset parameter is disabled
(cleared) by default.
Using the BCC
To reset the router, navigate to the dsucsu prompt (for example,
box
;
dsucsu/1/1
)
and type:
unit-reset
variable
For example:
dsucsu/1/1#
unit-reset reset