BCC show Commands
308648-14.00 Rev 00
B-45
show mct1e1 framer
The
show mct1e1 framer
command displays error information about the T1 and
E1 framers.
The output contains the following information:
Slot/Module/Conn Name of the physical interface.
Num Vld Intv Number of previous time intervals for which valid data was
collected. The value is 96 unless the interface was brought
on line within the last 24 hours. In this case, the value is the
number of complete 15-minute intervals since the interface
has been on line.
Bipolar Violation Counts Number of bipolar (line code) violations. The FDL counts
bipolar violations whether its synchronizer is in sync or not. If
the FDL is set to receive B8ZS code words, it does not count
these code words as bipolar violations.
CRC-4 Error Counts Number of CRC-4 errors. The FDL calculates CRC-4 on the
incoming data. Each time the calculation does not match the
CRC-4 code in the incoming enhanced super frame (ESF)
data stream, this count increments.
Far End Block Errors Number of far end block error counts.
Loss of Frame Failures Number of loss of frame failures; occur when an
out-of-frame event or carrier loss occurs. An out-of-frame
event occurs when at least two of four consecutive framing
bits are in error.
Loss of Signal Failures Number of loss of signal failures; occur when the receive
carrier is lost.
Alarm Indicat Failures Number of alarm indication failures; occur when two
consecutive frames have less than three zeros (total) in the
data stream.
Remote Alarm Failures Number of remote alarm failures; occur when the yellow
alarm is detected.