Configuring MCT1
6-29
Parameter: Remote Loopback Detection
Default: Disable
Options: Enable
| Disable
Function: Enables or disables detection of the driver’s own BOFL packets,
providing you set the Breath of Life (BOFL) Enable/Disable parameter to
Enable. If you select Enable and put the line into loopback mode the
downstream driver will bring down the interface when it detects its own
BOFL packets.
Instructions: Select Enable or Disable.
MIB Object ID: 1.3.6.1.4.1.18.3.4.9.6.1.56
Parameter: BERT Mode
Default: Disable
Options: Enable
| Disable
Function: Enables or disables BERT mode.
You can only configure this parameter for QMCT1 link modules.
Instructions: Select Enable or Disable.
MIB Object ID: 1.3.6.1.4.1.18.3.4.9.6.1.62
Parameter: BERT Test Pattern
Default: Ones
Options: Zeros
| Ones | QRSS | 2e15 | 2e15 Inverted | 2e20 | 2e23 | 2e23 Inverted
Function: Specifies the test pattern.
You can only configure this parameter for QMCT1 link modules.
Instructions: Select a test pattern.
MIB Object ID: 1.3.6.1.4.1.18.3.4.9.6.1.63
Comentários a estes Manuais