Customizing Synchronous and Asynchronous Lines
4-9
Parameter: Transmit Window Size
Default: 1
Range: 1 to 7 frames
Function: Controls the number of I-frames that can be transmitted without
acknowledgment.
Instructions: Either accept the default value, or enter a new value.
MIB Object ID: 1.3.6.1.4.1.18.3.4.5.1.27
Parameter: Minimum Frame Spacing
Default: 1
Range: 1 to 32 flags
Function: Specifies the number of flags transmitted between adjacent frames.
Instructions: Set this parameter to the appropriate number of flags.
MIB Object ID: 1.3.6.1.4.1.18.3.4.5.1.29