Configuring MCE1
5-21
To edit parameters for a logical line:
1. Select the line and circuit name from the logical line list.
Site Manager displays the circuit’s parameters.
2. Edit the parameters you want to change.
Refer to the following descriptions for guidelines.
3. Click on Apply.
Parameter: Enable/Disable
Default: Enable
Options: Enable
| Disable
Function: Enables or disables the logical line.
Instructions: Select Enable or Disable.
MIB Object ID: 1.3.6.1.4.1.18.3.4.9.6.1.2
Parameter: Breath of Life (BOFL) Enable/Disable
Default: Enable
Options: Enable
| Disable
Function: Enables or disables the transmission of BOFL packets. When you set this
parameter to Enable, a BOFL packet is sent out on the wire as often as the
value you specify for the BOFL Timeout parameter.
Instructions: Select Enable or Disable.
MIB Object ID: 1.3.6.1.4.1.18.3.4.9.6.1.8
Parameter: BOFL Timeout (seconds)
Default: 5 seconds
Range: 1 to 60 seconds
Function: Indicates the time period between Breath of Life packets.
Instructions: Set the time between BOFL packets in seconds.
MIB Object ID: 1.3.6.1.4.1.18.3.4.9.6.1.9