Avaya Configuring Line Services Manual do Utilizador Página 181

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 268
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 180
Configuring MCT1
6-11
Parameter: Line Coding
Default: B8ZS
Options: AMI
| B8ZS
Function: Selects a line coding method. AMI line coding is bipolar: a binary 0 is
transmitted as zero volts and a binary 1 is transmitted as either a positive
or negative pulse, opposite in polarity to the previous pulse. (When
configured for AMI line coding, the MCT1 link module remains
synchronized upon receiving up to 45 consecutive 0s.)
B8ZS (Bipolar with 8-Zero substitution) line coding replaces a block of
eight consecutive binary 0s with an 8-bit B8ZS code containing bipolar
violations in the fourth and seventh bit positions of the substituted code.
In the receive direction, the B8ZS code is detected and replaced with eight
consecutive binary 0s.
Instructions: Specify the line coding method.
MIB Object ID: 1.3.6.1.4.1.18.3.4.9.4.1.7
Parameter: Signal Level (dB)
Default: 0.0 dB
Options: -15 dB
| -7.5 dB | 0.0 dB | 0.5 dB | 0.8 dB | 1.1 dB | 1.5 dB
Function: Specifies the T1 transmit power level in decibels (dB).
The DS1 values of -15 and -7.5 dB are long-haul and the carrier
determines these values if 0.0 dB is not sufficient.
The DSX1 values of 0.0, 0.5, 0.8, 1.1, and 1.5 dB are short-haul and
correlate with cable length as follows:
Instructions: Specify the decibel level according to the length of the cable or as the
carrier specifies.
MIB Object ID: 1.3.6.1.4.1.18.3.4.9.3.1.6
0.0 dB 0 to 133 ft
0.5 dB 133 to 266 ft
0.8 dB 266 to 399 ft
1.1 dB 399 to 533 ft
1.5 dB 533 to 655 ft