Configuring Line Services
4-16
Parameter: Idle RR Frames
Default: Off
Options: On
| Off
Function: Indicates whether or not the router sends a Receiver Ready (RR) signal
when the Link Idle Timer expires.
Instructions: Accept the default or select On if you want the router to send RRs.
MIB Object ID: 1.3.6.1.4.1.18.3.4.5.1.61
Parameter: Cable Type
Default: Null
Options: Null
| RS232 | RS422 | V35 | X21
Function: Use only for switched-service lines. If the port is connected to a dial-up
device for switched services, use this parameter to specify the cable
interface type of the device.
Instructions: Set to reflect the cable interface type that connects the dial unit if you are
using one.
MIB Object ID: 1.3.6.1.4.1.18.3.4.5.1.83
Parameter: Retry Timer
Default: 300 tenths of a second (3 seconds)
Range: 1 to 99999 tenths of a second
Function: Indicates the time the router waits for a response from the link. The router
sends Link Control frames when this timer expires, and resends the
frames up to the value of the Retry Count parameter, then disconnects the
link.
Instructions: Enter a timeout value in tenths of seconds.
MIB Object ID: 1.3.6.1.4.1.18.3.4.5.1.21