
Configuring Line Services
5-36
Running the Tests
When you have set the test parameters, you can test the line.
To test the MCE1 line:
1. Start at the MCE1 Port Actions window (refer to Figure 5-21).
2. Click on the appropriate Send Command.
Refer to T
able 5-1 for a list of the commands and their functions.
3. Click on Apply.
4. Repeat Steps 2 and 3 for each test you want to run.
5. Click on Done.
The MCE1 Port Parameters window appears (r
efer to Figure 5-20). All
changes you apply to the port in the MCE1 Port Actions window are effective
only while the window is active. When you exit the MCE1 Port Actions
window, all port settings revert to the original port settings.
Caution: Wait until the MCE1 Port Actions window updates before selecting
another action.
Table 5-1. Send Commands for BERT Mode
Send Command Function
Reset BERT Counters Resets all counters to 0
Insert 1 Error Inserts a single (non-repeating) error
into the bit stream
Insert 1 Error/1K Inserts a deliberate error into every
thousandth position in the bit stream
Insert 1 Error/1M Inserts a deliberate error into every
millionth position in the bit stream
Disable Insert Error Stops the insertion of deliberate
errors into the bit stream
Comentários a estes Manuais