Parameter: KG84A Cycle
Default: 100 milliseconds
Options: 5
| 10 | 25 | 50 | 100 | 200 | 500
Function: Specifies the timer cycle’s length, in milliseconds. This cycle value is
used by the timers on the other KG84A devices on the network. This also
becomes the polling cycle for monitoring FCS errors.
Instructions: Accept the default or select one of the valid options, and be sure to set the
RTS Enable parameter to Enable.
MIB Object ID: 1.3.6.1.4.1.18.3.4.5.1.67
Parameter: KG84A Sync Loss Interval
Default: 50
Options: 2
| 5 | 10 | 25 | 50 | 100 | 200 | 500
Function: Specifies how many cycles the router should wait after detecting an FCS
error to receive a valid frame before declaring that a loss of
synchronization has occurred.
Instructions: Accept the default or select one of the valid options, and be sure to set the
RTS Enable parameter to Enable.
MIB Object ID: 1.3.6.1.4.1.18.3.4.5.1.68