Avaya Configuring DLSw Services Manual do Utilizador Página 250

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 249
Configuring DLSw Services
C-28
304233-A Rev. 00
SDLC does not connect to
the host computer.
SDLC interface not active
SDLC local devices not
configured properly
Source or destination MAC
address incorrect; if LLC
media is Ethernet, the
address needs to be in
non-canonical format
XID is incorrect
SDLC device configured for
NRZI
Check the configuration to
ensure that there is an SDLC
connection.
Check the DLSw local device
configuration.
Verify that the MAC address
is correct; if the LLC media is
Ethernet, then flip the
address format.
Obtain correct XID values.
Check the SDLC device and
set the Sync Line Coding
parameter.
The SDLC connection is up
and down.
Idle timeout too short for
some configurations
SDLC device configured for
half/full duplex
Increase the SDLC Idle Line
Timer parameter
(wfSdlcPortAdminIdleTimer).
For a half-duplex physical
line, set the RTS Enable
parameter to Enable or set
wfSyncRtsEnable to 1; for a
full-duplex data link, set the
Primary Full Duplex
parameter to Falsefull duplex
or set the variable
wfSdlcPortAdminPriFdplx to
2.
Table C-12. SDLC Troubleshooting
(continued)
Problem Possible Cause Action/Solution
Vista de página 249