Avaya Configuring DLSw Services Manual do Utilizador Página 245

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 244
Troubleshooting DLSw
304233-A Rev. 00
C-23
Table C-7. DLSw Interface Troubleshooting
Problem Possible Cause Action/Solution
The DLSw interface state is
DOWN.
Physical interface not up
DLC interface not up
Check the connections;
make sure that the physical
interface is up.
Check the DLC
configuration and delete the
interface, if necessary;
notify Bay Networks.
The DLC interface is
DOWN.
Physical interface not up Check the connections;
make sure that the physical
interface is up.
The DLSw interface is
DOWN; the LLC interface is
UP.
DLSw interface configured
on a different slot than
physical interface
DLSw interface different
than corresponding LLC
wfLlcInterfaceEntry.wfLlcIn
terfaceLlc2Cc
Potential LLC problem if not
notifying DLSw that it is
present
Check and correct the
configuration to ensure that
DLSw is configured on the
same slot as the physical
interface.
Correct the configuration;
DLSw must be configured
on the slot where DLC
termination occurs.
Delete the LLC interface;
contact Bay Networks.
Ethernet interfaces drop
sessions from Token Ring
interfaces.
Frames sent to Ethernet are
larger than 1500 bytes
Set the DLSw Virtual Ring
MTU parameter to 1518 or
less on any routers with
Token Ring.
Ethernet sessions establish
with difficulty.
Loops formed by dual router
Ethernet connections
Two DLSw routers
connected to an Ethernet
segment must have filters to
avoid loops.
Vista de página 244
1 2 ... 240 241 242 243 244 245 246 247 248 249 250 ... 271 272