DLSw Service Parameters
304233-A Rev. 00
A-21
Parameter: Initial Pacing Window
Path:
Configuration Manager > Protocols > DLSw > Advanced > Global
Default: 5
Range: 5 to 100
Function: Specifies the initial number of received data frames that the local DLSw router
permits during an established connection with another DLSw router running
RFC 1795 or DLSw Version 2 or RFC 2166. The two DLSw routers advertise
their initial pacing value to each other over capabilities exchange messages.
Instructions: Enter a value in the range 5 to 100. Depending on the amount of network traffic
during the session, the router may increase or decrease the pacing window size.
An increase in the window size means that the router is granting permission to
receive more data frames from the sending DLSw router. A decrease in the
window size means that the router is reducing the number of data frames that it
will accept from the sending DLSw router.
MIB Object ID: 1.3.6.1.4.1.18.3.5.1.5.1.27
Parameter: NetBIOS Session Alive Filter
Path:
Configuration Manager > Protocols > DLSw > Advanced > Global
Default: Enable
Options: Enable
|
Disable
Function: Enables or disables the NetBIOS session alive frame transmissions.
Continuously sending session alive frames can cause lines to remain active
unnecessarily, possibly increasing the usage cost of the line.
Instructions: Click on Values and select Enable or Disable. Select Enable to start the
NetBIOS session alive filter, stopping session alive frame transmissions. Select
Disable to cancel the filter and continue session alive frame transmissions every
30 seconds.
MIB Object ID: 1.3.6.1.4.1.18.3.5.1.5.1.29