Monitoring PPP Using the BCC show Command
308639-14.00 Rev 00
D-7
show ppp line config
The
show ppp line config
command displays information about the configured
PPP line parameter values for the specified interface.
The output contains the following information:
show ppp line params
The
show ppp line params
command displays information about the PPP line
parameters configured for the specified interface.
The output contains the following information:
Circuit The circuit for which this command displays information.
Slot/<Mod>/Conn The name of the physical interface.
LCP The operational state of the Link Control Protocol.
Restart Timer The number of seconds that the restart timer waits before
retransmitting data.
Echo Req Freq The number of seconds that the router waits between the transmission
of echo-request packets.
Echo Rep Loss The maximum number of unacknowledged echo-reply packets that the
router transmits before declaring the point-to-point link down.
Max Conf Req The maximum number of unacknowledged configure-request packets
that the router transmits before assuming that the peer router on the
other end of the link is unable to respond.
Max Term Req The maximum number of unacknowledged terminate-request packets
that the router transmits before assuming that the peer router on the
other end of the link is unable to respond.
Max Conf Fail The maximum number of configure-NAK packets that the router
transmits before sending a configure-reject packet for those options
that it does not agree with.
Circuit The circuit for which this command displays information.
Slot/<Mod>/Conn The name of the physical interface.
LCP The operational state of the Link Control Protocol.
Magic Number The operational state of the loopback test that the peer normally
performs as part of its network integrity checking.