PPP Parameters
308639-14.00 Rev 00
A-13
PPP Line Parameter Descriptions
Use the following guidelines to configure the PPP Lines parameters. The order of
presentation corresponds to the order of fields in the PPP Line Lists window, and
also (approximately) to the order of items in the wfPppLineEntry MIB. Figure A-2
shows the Site Manager PPP Line Lists window. In the path names that follow,
bold text indicates that in Site Manager, you invoke the PPP Line Lists window by
clicking on the Lines button on the PPP Interface Lists window.
Parameter: Fragmentation Trigger Size
Path: Protocols > PPP > Interfaces
Default: 256 (bytes)
Range: 64 through the maximum transmission unit for the circuit
Function: This parameter is active only for multilink. Specifies the minimum size of a
packet that multilink will fragment.
Instructions: When packet fragmentation over multilink is permitted, accept the default or
specify the minimum packet size that PPP will consider fragmenting.
MIB Object ID: 1.3.6.1.4.1.18.3.5.9.2.2.1.57