Starting Dial Backup Using the BCC
117353-B Rev. 00
3-13
5.
Create a backup pool.
Go to “Create a Backup Line Pool
” on page 3-9 for instructions.
6.
Add the backup lines to the backup pool.
Go to “Add a Backup Line to the Pool
” on page 3-10 for instructions.
7.
Go to “Specify the ISDN Switch Type” on page 3-14.
Configure PRI Lines
PRI lines are available only on the ASN™, BCN, and BLN hardware platforms
using the following link modules:
• Single or Dual Port Multichannel T1 Link Module (BLN and BCN)
• Dual Port Multichannel T1 Net Module (ASN)
• 120-ohm Single Port MCE1-II Net Module (BLN and BCN)
• 120-ohm Single or Dual Port MCE1-II Link Module (ASN)
• QMCT1 Link Module (BLN and BCN)
To configure PRI lines:
1.
Begin by configuring the leased interface. See “Creating a Leased
Interface for Backup Service” on page 3-6 for instructions.
2.
Create the physical interface for the backup PRI interface by entering:
mct1
<
slot/connector
>;
pri
or
mce1
<
slot/connector
>;
pri
For example:
box# mct1 3/1; pri
For more information about MCT1 and MCE1 parameters, see Configuring
WAN Line Services.
3.
Create a dial object for the PRI interface so the B channels can be
available as dial backup lines. Navigate to the pri prompt and enter:
dial