Parameter: Routing Update Hold Time
Path: Dialup > Demand Circuits > Demand Pools > FR Circuits >
FR Demand Circuits
Default: 0
Options: 0 to 600 seconds
Function: Tells the router how long to wait before sending RIP or SAP updates across the
Frame Relay demand circuit. This parameter works together with dial
optimized routing.
Instructions: If you enable dial optimized routing, enter the number of seconds that the
router should wait after placing a call to send routing updates. The time interval
you specify should be long enough so that the connection to the destination site
activates, not just the connection to the Frame Relay switch. If you send routing
updates before the connection to the destination is active, routing updates may
not reach the destination.
MIB Object ID: 1.3.6.1.4.1.18.3.5.1.4.5.1.57