Configuring Dial Services
A-40
117353-B Rev. 00
Parameter: Manual Standby Action
Path: Dialup > Demand Circuits > Demand Pools > PPP Circuits >
PPP Demand Circuits
Default: No Action
Options: No Action
|
Activate
|
Deactivate
Function: Allows you to manually control the standby circuit.
Instructions: Select Activate to activate a standby or hot standby circuit. Select Deactivate to
bring down a standby circuit. Accept the default, No Action, if you do not want
to manually activate a standby circuit.
MIB Object ID: 1.3.6.1.4.1.18.3.5.1.4.5.1.52
Parameter: Standby Primary Circuit
Path: Dialup > Demand Circuits > Demand Pools > PPP Circuits >
PPP Demand Circuits
Default: None
Options: Circuit number of a leased line.
Function: Specifies the primary circuit that the hot standby circuit backs up. This option is
available only if the Standby Mode parameter is Hot Standby.
Instructions: Click on the Values button. Site Manager displays a list of primary and
bandwidth-on-demand circuits. Highlight the circuit for which standby service
should be provided, then click on OK.
MIB Object ID: 1.3.6.1.4.1.18.3.5.1.4.5.1.4
Comentários a estes Manuais