Customizing Backup Circuits
117353-B Rev. 00
11-19
You can define the following schedule using both BCC and Site Manager.
Table 11-2. Scheduling Options
Parameter Function
days
Specifies the days that this circuit should be available. The router
uses this parameter together with a start time and end time that
you specify to create a time period that the circuit can be available.
The options are: Sunday, Monday, Tuesday, Wednesday, Thursday,
Friday, Saturday, Weekday, Weekend. Individual days of the week
take precedence over the Weekday option.
start time
Specifies the time of day the demand or backup circuit is available.
The router uses this parameter and the End Time parameter to
establish a time period when the circuit is available. This parameter
also specifies the time of day any secondary lines are available if
you configure bandwidth-on-demand service for a PPP demand
circuit.
For the router to activate the circuit at the configured start time,
ensure that the Availability Mode parameter is set to the default,
Available. If you do not want the router to activate the circuit at the
start time, set the Availability Mode to Not Available.
end time
Specifies the time of day the demand or backup circuit is no longer
available. The router uses this parameter and the Start Time
parameter to establish a time period when the circuit is available.
This value also specifies the time of day that all secondary lines
are deactivated if you set up bandwidth-on-demand service for a
PPP demand circuit.
For the router to deactivate the circuit at the configured end time,
ensure that the Availability Mode parameter is set to the default,
Available. If you do not want the router to deactivate the circuit at
the end time, set Availability Mode to Not Available.
(continued)