Parameter: Modem Factory Defaults
Path: COM Connector > Edit Modem > Edit V.34 Modem Interface Parameters
Default: Enabled
Options: Enabled
|
Disabled
Function: Specifies whether exclusive use of the factory default modem initialization
string is enabled or disabled. When enabled, the router sends only the default
string (
ATT&d0&k3&X0S0=2S2=43) to the modem. When disabled, the router
sends a user-specified initialization string (set in the Modem Config String
parameter) after sending the default string. Commands in the user-specified
string take precedence over the factory default command string.
Instructions: Enable or disable the exclusive use of the factory default modem initialization
string.
MIB Object ID: 1.3.6.1.4.1.18.3.4.29.1.1.8
Parameter: Originate/Answer
Path: Configuration Manager > COM Connector > Edit Modem > Edit V.34 Modem
Interface Parameters
Default: Originate
Options: Originate
|
Answer
Function: Determines whether the modem answers or originates calls.
Instructions: Set the modem to answer or originate calls.
MIB Object ID: Not applicable
Parameter: Phone Number
Path: COM Connector > Edit Modem > Edit V.34 Modem Interface Parameters
Default: None
Options: An ASCII text string.
Function: Specifies the number to dial for calls that the modem originates.
Instructions: Enter a complete dial-out phone number, including applicable country and area
codes. Valid dial modifiers are the comma, exclamation point, ampersand (&),
hyphen, and parenthesis.
MIB Object ID: 1.3.6.1.4.1.18.3.4.29.1.1.18