Reading the Event Log
A-33
The same unscheduled message shown in Line 8 earlier applies to FDL Line Loop
IA and IB.
If you click on FDL Disable ALL, the MIB entity disables all FDL line loops. It
sends a “Universal Loopback Deactivate” message.
# 16: mm/dd/yy 10:58:54.840 INFO SLOT 2 MIB Code: 5
wfDs1E1ActionEntry.5.905102 set to 7
# 17: mm/dd/yy 10:58:54.871 INFO SLOT 4 DS1E1 Code: 32
Connector COM1 Unscheduled FDL message received - type Universal
Loopback Deactivate.
If you click on Loop Up, the line goes into a loopback state. The only visible
evidence of this state is that the loopback LED lights. The log shows the
following:
# 2: mm/dd/yy 11:02:41.489 INFO SLOT 2 MIB Code: 7
wfSnmp.3.0 set to 192.32.18.9
# 3: mm/dd/yy 11:02:41.552 INFO SLOT 2 MIB Code: 5
wfDs1E1ActionEntry.4.905102 set to 1
# 4: mm/dd/yy 11:02:47.292 INFO SLOT 4 DS1E1 Code: 22
Connector COM1, Logical Line 1 LLC service withdrawn.
The following command displays the new port status:
[3:1]$ show ds1e1 port
DS1E1 Port Status:
------------------
2 entries in table.
If you click on Loop Down, the MIB entity disables the Line loopback and the log
shows the following:
[3:1]$ log -fftwid
# 2: mm/dd/yy 11:06:25.815 INFO SLOT 2 MIB Code: 7
wfSnmp.3.0 set to 192.32.18.9
# 3: mm/dd/yy 11:06:25.918 INFO SLOT 2 MIB Code: 5
wfDs1E1ActionEntry.4.905102 set to 2
# 4: mm/dd/yy 11:06:31.675 DEBUG SLOT 4 DS1E1 Code: 50
Connector COM1, Logical Line 1 time_slot = 1.
Connector COM1, Logical Line 1 time_slot = 2.
Slot Conn State MTU Loopback
State
Accept
Loopback
BERT
Mode
Line
Type
Line
Coding
FDL
Type
FDL
Addr
4 1 Loopback 1600 Net Line Enabled Off ESF B8ZS ANSI BY
5 2 Up 1600 No Loop Enabled Off ESF B8ZS ANSI BY