Chapter 2 System telephony networking overview 65
BCM 4.0 Networking Configuration Guide
Certain situations result in Route Optimization not taking place. For example, calls that are using
Hold, Parking or Camp features do not undergo Route Optimization, and if a Route Optimization
call undergoes Diversion, the Route Optimization is dropped.
Setting Route Optimization
There is no system programming required for the feature when BCM is working as a terminating
PBX system. However, BCM must have a private access code programmed that maps to a valid
destination code or line pool code on DPNSS lines. Further, Allow Redirect must be selected.
Loop avoidance
Errors in the configuration of a network may make it possible for a call to be misrouted, and arrive
at a PBX system through which it has already passed. This would continue, causing a loop which
would eventually use up all of the available channels. The Loop Avoidance service permits
counting of DPNSS 1 transit PBXs and rejecting a call when the count exceeds a predetermined
limit.
Private networking with DPNSS
(International only)
DPNSS supports the Universal Dialing Plan (UDP), an international standard for sending and
receiving private numbers over networks. The UDP requires that a dialing number include the
following:
• a Private Access Code, programmed into the system as part of the destination code table to
prevent conflicts with the internal numbering system. (Access Codes)
• a Home Location Code (HLC) assigned to each PBX system, and configured as part of the
destination code (a maximum of seven digits). For each HLC, a destination code must be
programmed in the system. (Configuration > Telephony > Dialing Plan > Private
Networking)
• a Directory Number (DN) assigned to each extension as a line appearance. The DN appears as
the last string segment in a dialed number. In the number 244-1111, 1111 is the DN.
A typical Private Number, using a private access code and dialed from another site on the network,
appears below.
In this networking example, a private network is formed when several systems are connected
through a Meridian 1 and a terminating BCM system. Each site has its own HLC and a range of
DNs. Figure 11 illustrates this example.
Private Access Code + Home Location Code + Directory Number = Calling Party Number
6 + 848 + 2222 = 6-848-2222
Comentários a estes Manuais