546 Chapter 62 Configuring the Dial-up resources
N0060606N0060606
1 Click Configuration > Resources > Network Interfaces > Interfaces tab.
2 Click the Modem interface to configure.
3 Click the Link Parameters tab.
The Link Parameters panel appears. See Figure 168.
4 Configure the Modem Link Parameters. Refer to the information in Table 123.
Figure 168 Link Parameters
Table 123 Modem link parameters (Sheet 1 of 2)
Attribute Value Description
Link Parameters
Dial-out number <numeric> Type a telephone number to use to connect using the modem interface. If
needed, include area codes and all necessary digits to dial an external
number.
Maximum receive
unit
<128-16384> The largest incoming packet size the modem will handle.
Default: 1500.
Maximum
transmission unit
<128-16384> Maximum size of the packets that will be sent.
Default: 1500.
Disconnect time (s) <numeric> Enter the interval, in seconds, during which the modem interface
disconnects when there is no traffic.
Select 0 if you want the BCM to close the connection when the far end
hangs up.
Specifying a value of 0 makes the connection persistent.
Note: If you have more than one Trap Community Entry configured with
this dial up interface, using a very small number for the Disconnect Time
will put you at risk of a racing condition. To reduce the racing condition,
enter a larger value for the Disconnect Time.
Advanced Parameters
Connect rate 57600
38400
19200
9600
4800
Specify the initial speed (in bits per second) for the modem to connect.
Set to the maximum permissible value for best results.
Note: This is the initial rate; the actual rate is always negotiated.
Default: 57600