Installing IP500/IP500 V2 Page 225
15-601042 Issue 28g (11 October 2013)IP Office 9.0
System Components: IP500 Base Cards
10.3.4 BRI Combination Card
This card is used to add a combination of ports to an IP500 V2 control unit. Not supported by IP500 control units.
· Supports
· 10 voice compression channels. Codec support is G.711, G729a
and G.723 with 64ms echo cancellation. G.722 is supported by
IP Office Release 8.0 and higher.
· 6 Digital Station ports for digital stations (except 3800,
4100, 4400, 7400, M and T-Series).
· 2 Analog Extension ports.
· 2 BRI Trunk ports (4 BRI channels).
· 10 voice compression channels. Codec support is G.711, G729a
and G.723 with 64ms echo cancellation. G.722 is supported by
IP Office Release 8.0 and higher.
· IP500 Control Unit:
· IP500 V2 Control Unit:
· Maximum per Control Unit: 2 combination cards of any type.
· IP Office Basic Edition - Norstar Mode and IP Office Basic Edition
systems are limited to a maximum of 12 BRI channels using BRI
Combination and or BRI trunk daughter cards.
· IP500 Trunk Card Support: 1. The trunk daughter card is pre-
installed and cannot be replaced with another card type.
Provides DS ports for digital stations (except 4100, 4400, 7400, M and T-Series).
LEDs
· Green Flashing = Phone detected.
· Green On = Phone active.
· LED1 is also used for base card status:
· Red On = Error
· Red Slow Flash = Initializing.
· Red Flash every 5 seconds = Card
okay.
· Red Fast Flash = System shutdown.
· Supports ICLID modes DTMFA, DTMFC, DTMFD, FSK and UK20.
· REN 2 (1 for external bell device).
· Off-Hook current: 25mA
· Ring Voltage: 40V.
· Intended for connection to two-wire analog phones, the ports do not include a ringing
capacitor. For connection to 4-wire analog phones, connection should be via a master
socket with ringing capacitors.
· No status LEDs are used for analog phone extensions.
· Each trunk port supports 2B+D channels.
· ETSI or AusTS013 basic rate protocol set through the IP Office configuration.
LEDs
· Off = No trunk present.
· Green on = Trunk present.
· Green flashing = Trunk in use.
· LED 9 is also used for daughter card status.
· Red On = Error
· Red Slow Flash = Initializing.
· Red Flash every 5 seconds = Card
okay.
· Red Fast Flash = System shutdown.
IPO IP500 V2 COMB CARD BRI
IPO IP500 V2 COMBINATION CARD BRI
48
394 48
Comentários a estes Manuais