Using Technician Interface Scripts
A-4
Capture Direction Options
-------------------------
1: Receive
2: Transmit
3: Receive and Transmit
Current value for Capture Direction is 1
Press return for current value or enter new value: 3
Receive Trigger Options
-----------------------
1: Stop Capture when Capture Buffer is Full
2: Stop Capture when Receive Filter One is Matched
3: Stop Capture when Receive Filter Two is Matched
4: No Receive Trigger
Current value for Receive Trigger is 4
Press return for current value or enter new value: 4
Transmit Trigger Options
-----------------------
1: Stop Capture when Capture Buffer is Full
2: Stop Capture when Transmit Filter One is Matched
3: Stop Capture when Transmit Filter Two is Matched
4: No Transmit Trigger
Current value for Transmit Trigger is 4
Press return for current value or enter new value: 4
Packet Capture Receive Capture Filter Configuration
---------------------------------------------------
Receive Filter One Type Options
-------------------------------
1: Capture
3: Not Used
Current value for Receive Filter One Type is 3
Press return for current value or enter new value: 1
Current value for Receive Filter One Offset is 0
Press return for current value or enter new value: